controls the display of leading and trailing zeros in dimensions.
std_default*—displays only trailing zeros. no leading zeros are displayed.
std_metric—displays only leading zeros. trailing zeros are not displayed.
std_english—displays only trailing zeros. leading zeros are not displayed.
both—both leading and trailing zeros are displayed.
note:
if the lead_trail_zeros_scope drawing setup option is set to all, the lead_trail_zeros drawing setup file option controls the display of leading and trailing zeros in dimensions, hole parameters within hole notes, and all floating point parameters on a drawing, including parametric notes, view scale notes, tables, symbols, and cosmetic thread notes.
in case of dual dimensioning, the lead_trail_zeros drawing setup file option controls the use of leading and trailing zeros in both std_english and std_metric standards independently.
if the units in the dual_dimensioning drawing setup file option are primary[secondary], std_english[std_metric] shows the primary units values with trailing zeros, while the secondary units show values with leading zeros.
if the units in the dual_dimensioning drawing setup file option are secondary[primary], std_english [std_metric] secondary units show values with trailing zeros, while the primary units show values with leading zeros.
hole parameters within the hole notes appear with 3 decimals, regardless of the value set for the default_dec_places configuration option. if you want to change the number of decimal places for the hole parameter, type [.n] after the parameter in the text tab of the note properties dialog box. here, n is the number of decimal places. you can edit the hole parameter values only through the note properties dialog box that opens when you select the hole note and click edit > value. alternatively, to edit hole parameter values through the note properties dialog box, select the hole note, right-click, and click edit value on the shortcut menu.