creo3 config.pro option documentation for: IGES_OUT_ASSEMBLY_DEFAULT_MODE            


iges_out_assembly_default_mode

flat * , one_level , all_levels , all_parts
Specifies the default for export of assemblies through IGES. The optional values are:
flat - Converts the assembly to a single-level geometric model.
one_level - Exports only the assembly structure with pointers to component files.
all_levels - Exports the assembly structure to a single file and the components to IGES files.
all_parts - Exports an assembly to IGES as multiple files containing geometry information about the assembly components and assembly features, if any.